Enter Part #
Contact Information
Add: CARSPA Building, Xinhejia Industrial Zone, Baishi, Yueqing, Zhejiang, 325604 China
|
|
|
||||||||||||||||||||||||
Connector Wire Size: 7*9.5mm L, N: AC Input
: Earth Ground DC Output: +V1, +V2, -V3 COM: DC Output Public Ground
|
Order No. |
T-60A |
T-60B |
T-60C |
||||||
|
DC Output |
5V, 0.5~7A |
12V, 0.2~3.5A |
-5V, 0~1A |
5V, 0.5~7A |
12V, 0.2~3.5A |
-12V, 0~1A |
5V, 0.5~7A |
12V, 0.2~3A |
-15V, 0~1A |
|
Output Voltage Range |
±2% |
±6% |
±6% |
±2% |
±6% |
±6% |
±2% |
±6% |
±6% |
|
Wave and Noise |
100mV |
100mV |
100mV |
100mV |
100mV |
100mV |
100mV |
100mV |
100mV |
|
Efficiency |
70% |
72% |
72% |
||||||
|
AC Input Voltage Range |
88~264VAC 47~63Hz; 120~370VDC |
||||||||
|
Input Current |
2A/115V 1A/230V |
||||||||
|
AC Inrush Current |
Cold-start Current 30A/115V 60A/230V |
||||||||
|
Leakage Current |
<3.5mA/240VAC |
||||||||
|
DC Adjustable Range |
±10% Rated Output Voltage |
||||||||
|
Overload Protection |
105~150% Cut off the Output, Auto-recovery |
||||||||
|
Over-voltage Protection |
115~135% Cut off the Output, Auto-recovery |
||||||||
|
Setup Rise Hold-up Time |
300ms 50ms 80ms/230VAC |
||||||||
|
Withstand Voltage |
I/P-O/P: 1.5KvAC 1min. I/P-FG: 1.5KvAC 1min. O/P-FG: 0.5KvAC 1min. |
||||||||
|
Working Temperature |
-10℃~+60℃,20%~90% RH |
||||||||
|
Size |
159*98*38mm |
||||||||
|
Weight/ Packing |
0.56Kg, 45pcs/26Kg |
||||||||