Enter Part #
Contact Information
Add: CARSPA Building, Xinhejia Industrial Zone, Baishi, Yueqing, Zhejiang, 325604 China
|
|
|
||||||||||||||||||||||||
Connector Wire Size: 5*9.5mm
L, N: AC Input
: Earth Ground DC Output: +V, -V
|
Order No. |
HSF-75-5 |
HSF-75-12 |
HSF-75-15 |
HSF-75-24 |
|
DC Output |
5V, 0~15A |
12V, 0~6.3A |
15V, 0~5A |
24V, 0~3.2A |
|
Output Voltage Range |
±2% |
±1% |
±1% |
±1% |
|
Wave and Noise |
80mV |
120mV |
120mV |
120mV |
|
Efficiency |
76% |
82% |
83% |
85% |
|
AC Input Voltage Range |
88~264VAC 47~63Hz; 125~370VDC |
|||
|
Input Current |
1.6A/115V 0.85A/230V |
|||
|
AC Inrush Current |
Cold-start Current 18A/115V 36A/230V |
|||
|
Leakage Current |
<2mA/240VAC |
|||
|
DC Adjustable Range |
±10% Rated Output Voltage |
|||
|
Overload Protection |
105~135% Hiccup Mode, Auto-recovery |
|||
|
Over-voltage Protection |
115~135% Cut off the Output, Auto-recovery |
|||
|
Setup Rise Hold-up Time |
500ms 20ms 60ms |
|||
|
Withstand Voltage |
I/P-O/P: 3KvAC 1min. I/P-FG: 1.5KvAC 1min. O/P-FG: 0.5KvAC 1min. |
|||
|
Working Temperature |
-10℃~+60℃,20%~90% RH |
|||
|
Size |
129*98*38mm |
|||
|
Weight/ Packing |
0.4Kg, 45pcs/19Kg |
|||